THE ULTIMATE OVERVIEW TO SETTING UP YOUR IP PA SYSTEM EFFECTIVELY

The Ultimate Overview to Setting Up Your IP PA System Effectively

The Ultimate Overview to Setting Up Your IP PA System Effectively

Blog Article

Network PA System for tool to large projects



Introduction


The XC-9000 system is a completely digital network PA system based upon the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes sure the efficient and proper transmission of all data packages. Not just can it make use of existing local area network, such as LANs or the Web, to transmit broadcast signals, however likewise it can likewise be released on a devoted broadcasting network.


A single-server system can sustain up to 3000 terminals and permits for server plunging. There are no restrictions on the concurrent program networks, accomplishing true complete electronic broadcasting.


System Features



Adaptable PA System Style


The PA system architecture is basic, consisting of solution administration software, network microphones, network amplifiers, network audio speakers, and various other devices.All devices is connected via the TCP/IP intranet procedure, allowing for versatile arrangement and simple administration of the system, with free control over broadcast content, network gadgets, and regions via the network.


Ip Paging SystemIp Pa System
Comprehensive Sound Management


The audio monitoring software consists of built-in attributes for producing broadcast plans, adaptable zoning, and pre-scheduled broadcasts.It sustains 24-hour shows, enabling for changing setups throughout all the time


Versatile Audio Source Assistance


The system sustains various forms of audio sources for sending notices like real-time speech and BGM playback. Audio sources can come from electronic music apps, CD/DVD gamers, microphones, and so on. In addition, the system supplies diverse features of supporting various broadcasting features such as set up broadcasting, zoned broadcasting, and emergency situation broadcasting.


Smoke Alarm System Integration


The system has a smoke alarm feature and can be integrated into a fire alarm system. When the alarm system main system obtains the startling signals, the cord will transfer the signal to tools, which triggers the XC-9000, sending out signals to speakers


Users could choose to pre-programmed settings to trigger full-area or zoned alarm systems in emergencies. The alarm voices come in several forms and might be modified providing to needs. As an example, customers can transform language settings, upload and edit their audio resources according to specific requirements, such as intruding alarm systems, smoke alarm or air aid alarm systems, and so on





Emergency Alarm System Assimilation


The system has an emergency alarm feature and can be incorporated into a smoke alarm system. When the alarm main device gets the startling signals, the wire will transmit the signal to devices, which causes the XC-9000, sending out signals to speakers


Customers can choose to pre-programmed setups to trigger full-area or zoned alarms in emergency situations. The alarm system voices been available in multiple kinds and can be edited accommodating demands. For instance, users can change language setups, upload and edit their audio resources according to specific requirements, such as intruding alarms, fire alarm systems or air help alarm systems, etc





Application Control for System Workflow


The system allows mobile app login and use, enabling users to initiate programs and various other operations to accredited terminals with the server software program, guaranteeing a convenient and structured experience.


Integrated SIP Compatibility


The system not only enables SIP phones to visit, however additionally can be linked to third-party SIP server or IPPBX, which develops a totally integrated and compatible communication system through seamless assimilation into existing systems.


Open up SDK


When big project like smart park occurs, the system gives an open SDK incorporated into third-party application platforms - IP Paging System


System Infrastructure



Key Features


Arranged Playback


The system has the ability to automatically transmit according to the arranged jobs as long as individuals post the audio documents for each amount of time of the day to the web server and produce a playback routine.


Zone Broadcasting


The system can randomly split a few network tools into different zones to play specified audio programs or send announcements to any kind of marked area. The volume of each device can be remotely changed.


Real-time Broadcasting


The system can capture and relay radio programs or various other exterior audio sources in real-time, and at the very same time broadcast them in sync.


Emergency Alarm Integration


The system can be integrated with the emergency alarm system for control. When an emergency alarm signal is triggered, it immediately triggers the emergency broadcast function and supports surrounding floor alarms. It also enables hand-operated emergency broadcasting by clicking a solitary switch.


SIP Phone Assimilation


The system can be why not try this out incorporated with SIP servers, enabling live speech of voice broadcasting using SIP phones to send statements anytime and anywhere.


CCTV Integration


The electronic devices such as IP POE Speakers embraces the global typical ONVIF method, which allows their voices to be broadcast by means of VMS systems. The terminals can likewise be integrated with CCTV systems for integrated broadcast.


Main Products



Sound Monitoring Software Program XC-9000


B/S design, supports cross-platform applications.
Covers conventional broadcasting system operates, permitting dividers monitoring.
Unified management of terminals within the system, viewing work standing, and batch volume change, and so on.
Sustains structure multi-level web server styles, deploying administration according to customer geographical areas.
Supplies SDK growth packages for second development and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Communication Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Intercom: Supported, Built-in Microphone.
Operating Temperature: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Procedures: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Running Temperature level: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Reaction: 45Hz~ 18KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Action: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 60Hz~ 18KHz.
Running Temperature: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Mixing Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Reaction :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP Interface Unit NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Protocol: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outputs.
Operating Temperature: -10~ 50 ℃.
Measurements: 483x259x44mm.


Solution For School





Adaptable Zoning Program:


The completely network terminals can understand adaptable zoning options, enabling relaying notifications to various areas or private terminals ( gadgets).


College Bell System:


It offers institution bell system at the beginning/ending of the course - IP Speaker. Multiple circumstances can be developed, including different arranged program jobs according to summer/winter timetable


Smoke Alarm Integration


It sustains integration with emergency alarm systems, enabling emergency Click Here alarm signals to be integrated right into the PA system.


Classroom Audio Boosting


Terminals support day-to-day applications in class scenes. They can be connected to projectors or interactive white boards for audio amplification.


Ip Paging MicrophoneIp Speaker

Smart Street Lamp/Security Pole



Support SIP Protocol:


Integrated SIP procedure for seamless assimilation with network interaction systems.


VMS Platforms Assimilation:


Integrated ONVIF protocol for integration with VMS systems.


Third-Party Assimilation:


Constructed In HTTP API for assimilation with 3rd party systems.


Voice Alarm Setting Off:


Constructed in alarm system input interface for activating voice alarms with electronic cameras.


Remedy For Hotel



Zone Control by Floor:


The system uses full network settings, splitting zones depending on different floorings and control over each zone individually.


Smoke Alarm Combination:


The system can be incorporated with smoke alarm system, making it possible for integration of smoke alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It supports programmable set up broadcasting, permitting adaptable plans according to various needs.


Emergency situation Broadcasting:


It sustains emergency broadcasting for the entire area, making it possible for one-click emergency situation interaction.


Solution For Manufacturing facility



Area Broadcasting:


It permits broadcasting to any area, assuring no disturbance in between different locations.


Alarm system Triggering:


Terminals have various kinds of user interfaces, making it possible for to set off alarm systems when connected with video cameras.


All Network Gadgets:


Release of completely network tools significantly reduces the difficulty of operating such as inspecting Learn More Here gadgets on harmful sites, and therefore safeguarding individuals and property.


The deployment of all network devices considerably lowers the problem of operation and upkeep monitoring


Integrated SIP Phones:


The system can be incorporated with SIP phone and program notices making use of SIP phones at any type of time and anywhere. Two-way sound talkback in between SIP phones and IP POE Audio speakers makes it easy for inspecting gadgets resting in office or other offices.


The XC-9000 system is a totally electronic network PA system based on the TCP/IP procedure. By leveraging the TCP/IP protocol, the system guarantees the efficient and correct transmission of all information packages. The system sustains various types of audio resources for sending notices like live speech and BGM playback. In addition, the system offers varied features of sustaining numerous broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page